Educational Equipments Manufacturer, Exporters & Suppliers - School Educational Equipments Manufacturers & Exporters of Educational Equipments for Lab. Science Lab Products, Teaching Aids, Classroom Instruments, Educational Laboratory
Flame Photometer, Digital, Single Channel
- Simple & Easy to Operate.
- Narrow Band Interference Filters.
Flame Photometer Unit
- No. of Filters: Na & K (Ca & Li are optional. Only available if specified at an extra cost)
- Range: Na: 0-100 ppm K: 0-100 ppm Ca: 20-100 ppm (optional) Li: 10-100 ppm (optional)
- Sensitivity: Na: 5 ppm K: 5 ppm Ca: 10 ppm (optional) Li: 10 ppm (optional)
- Display: 2 ½ digit bright LED Display
- Accuracy: + 2% upto 40 ppm + 5% above 40 ppm
- Repeatability: +2 Count
- Detector: Silicon Photodiode
- Filters: Narrow band interference glass filters
- Nebulizer: Black Bakelite, axial flow type
- Flame System: LPG and dry oil free air
- Warm-up time: 10 minutes
- Power: 230V + 10% AC 50Hz
- Weight: 6.5kg (approx.)
Compressor Unit
- Air Supply: By oil free mini compressor unit with pressure regular
- Combustion: LPG controlled by precision regulator
- Power: 230V +10% AC 50Hz
- Weight: 9Kg (approx.)
Accessories:
- Instrument with Na & K filters
- Instruction Manual
- Dustcover
- Chimney
- Air Tubing
- Operation Manual
Catalog No. |
Particulars |
SLEP1600 |
Flame Photometer, Digital, Single Channel |
Flame Photometer, Digital, Dual Channel
- Simple & Easy to Operate.
- Narrow Band Interference Filters.
- Dual Channel Display
- Na & K at single aspiration.
Flame Photometer Unit
- No. of Filters: Na & K (Ca & Li are optional. Only available if specified at an extra cost)
- Range: Na: 0-200 meq/litre K: 0-100 meq/litre Ca: 0-2 meq/litre (optional) Li: 0-10 meq/litre (optional)
- Display: Dual 2½ digit bright LED display
- Accuracy: ± 2% upto 100 meq/litre ± 5% above 100 meq/litre
- Repeatability: +2 Count
- Detector: Silicon Photodiode
- Filters: Narrow band interference glass filters
- Nebulizer: Black Bakelite, axial flow type
- Flame System: LPG and dry oil free air
- Warm-up time: 10 minutes
- Power: 230V + 10% AC 50Hz
- Weight: 7.5kg (approx.)
Compressor Unit
- Air Supply: By oil free mini compressor unit with pressure regular
- Combustion: LPG controlled by precision regulator
- Power: 230V +10% AC 50Hz
- Size (LxBxH): 275x192x240mm
- Weight: 9Kg (approx.)
Accessories:
- Instrument with Na & K filters
- Instruction Manual
- Dustcover
- Chimney
- Air Tubing
Catalog No. |
Particulars |
SLEP1610 |
Flame Photometer, Digital, Dual Channel |
Flame Photometer, Microprocessor Based
- Single Channel
- Mixing Chamber designed for stable flame
- Stainless steel round burner
- Concentric Non-Corrosive Nebulizer
- Narrow Band interference Filters
- 5 digit seven segment bright red LED display
Technical Specification
- Range: Serum (ppm) Urine (Meq/litre)
Na: 0.1 to 100 0.435-435 0.87-870
K: 0.1 to 100 0.256 - 256 0.512-512
Ca: 15 to 100 ------ ------
Li: 0.5 to 100 0.724-144.8 ------
- Accuracy: ± 1 % up to 40 ppm ± 2 % above 40 ppm
- Readout: 5 digit seven segment bright red LED display
- Flame System: LPG & dry oil free air
- Detector: Photodiode
- Calibration: 3 point calibration
- Power: 230V ± 10% AC,50Hz
- Weight: 8 Kg (approx.)
- Air Supply: By oil free mini compressor unit with pressure regulator
- Combustion Gas: LPG
- Atomizer: Axial flow type
- Burner: Stainless Steel
Standard Accessories
- Sample Holder (5 Nos)
- Dust Cover
- Main Lead
- Chimney
- Capillary tubes(3 Nos)
- Air and Gas Tubing along with End Clamps (1 Set)
- Cleaning Wire
- Instruction Manual
Catalog No. |
Particulars |
SLEP1620 |
Flame Photometer, Microprocessor Based |
Photocolorimeter, 8 Filters, Microprocessor Based,Table Model
- Highly accurate & stable.
- Range 400 to 700nm.
- 16x2 line backlit alphanumeric LCD display.
- Printer attachment facility
- Storage for 100 samples
- Soft touch membrane keys
Technical Specification
- Wave Length Range: 400 to 700 nm
- Resolution: 1%T, 0.01Abs., 0.01 Conc., 0.01 K Factor
- % Transmission: 0-100% T
- Absorbance: 0-1.99A
- Concentration: 0-19999
- K Factor: 1-19999
- Display: 16x2 line alphanumeric LCD display with backlit
- Keyboard: 8 Keys, soft touch membrane keys
- Data Storage: Up to 100 Samples
- Light Source: 6.8V, 0.3 Amp. Tungsten lamp
- Sample System: 10mm path length matched glass test tubes
- Filters: 400, 420, 480, 500, 520, 540, 620, 680nm
- Printer Interface: Centronics parallel Printer interface for any dot matrix printer
- RS232 Interface: Available (On Request)
- Weight: 2.5 Kg (approx.)
- Power Supply: 230V AC ±10%, 50Hz. with in-built Stabilizer
Accessories
- Matched Test Tube Set of 5
- Operation Manual
- Dust cover.
- Manual.
Catalog No. |
Particulars |
SLEP1630 |
Photocolorimeter, 8 Filters, Microprocessor Based,Table Model |
Photocolorimeter, 8 Filters, Digital, Table Model
- 1 ml solution measurements.
- Standard glass filters.
- Highly stable & accurate.
Technical Specification
- Std. Glass Filter: 8
- Mini Volume: 1ml
- Display: 2½ Digit LED
- Range: 400-700 nm
- Output: OD (0 to 1.99)
- Resolution: OD: 0.01
- Accuracy: 0.5% FSI
- Detector: Selenium photocell
- Light Source: 6.8V, 300mA
- Power: 230V± 10% and in-built battery
- Filters: 400, 420, 480, 500, 520, 540, 620, 680 nm
Accessories
- Set of 5 test tube.
- Spare lamp.
- Dust cover.
- Manual.
Catalog No. |
Particulars |
SLEP1640 |
Photocolorimeter, 8 Filters, Digital, Table Model |
Photocolorimeter, 5 Filters, Digital, Table Model
- 1 ml solution measurements.
- Standard glass filters.
- Highly stable & accurate.
Technical Specification
- Std. Glass Filter: 5
- Mini Volume: 1ml
- Display: 2½ Digit LED
- Range: 400-700 nm
- Output: OD (0 to 1.99)
- Resolution: OD: 0.01
- Accuracy: 0.5% FSI
- Detector: Selenium photocell
- Light Source: 6.8V, 300mA
- Power: 230V± 10% and in-built battery
- Filters: 420, 480, 540, 620, 680 nm
Accessories
- Set of 5 test tube.
- Spare lamp.
- Dust cover.
- Manual.
Catalog No. |
Particulars |
SLEP1650 |
Photocolorimeter, 5 Filters, Digital, Table Model |
Photocolorimeter, Auto Zero, Digital, Table Model
- Display both absorbance & %T models.
- Range 400 to 700nm.
- Fast & accurate operations.
- Automatic zero calibration.
- 1ml. solution measurement.
- Standard german glass filters.
Technical Specification
- Std. Glass Filter: 8
- Mini Volume: 1ml
- Display: 3 Digit, Bright Red 7 Segment LED
- Range: 400-700 nm
- Output: (0 to 1.99), %T: 0 to 199
- Resolution: OD : 0.01, %T : 1%
- Accuracy: 0.5% FSI
- Detector: Selenium photocell
- Light Source: 6.8V, 300mA
- Power: 230V ± 10%, 50 Hz. AC
- Dimensions (l x b x h): 220x180x125mm (approx.)
- Weight: 2 Kg (approx.)
Accessories
- Set of 5 test tube.
- Spare lamp.
- Dust cover.
- Manual.
Catalog No. |
Particulars |
SLEP1660 |
Auto Zero, Photocolorimeter, Digital, Table Model |
TDS Meter, Digital, Pocket Model
Innovated rich oxygen air-acetylene flame analysis technique
Type A
- Range: 10-1900 ppm
- Resolution: 10 ppm
- Typical EMC Deviation: ± 2% Full Scale
- Accuracy: ± 2% Full Scale
Type B
- Range: 100-10000 ppm
- Resolution: 100 ppm
- Typical EMC Deviation: ± 2% Full Scale
- Accuracy: ± 2% Full Scale
Catalog No. |
Particulars |
SLEP1670 |
TDS Meter, Digital, Pocket Model Type A |
SLEP1671 |
TDS Meter, Digital, Pocket Model Type B |
TDS Meter, Digital, A.T.C. , Waterproof, Pocket Model
- Range TDS: 0-19990 ppm
- Range Temperature: 0°C-55°C
- Resolution TDS: 10 ppm
- Resolution Temperature: 0.1°C / 0.1°F
- Accuracy TDS: + 2% Full Scale
- Accuracy Temperature: + 1°C
With Automatic Temperature Compensation
Catalog No. |
Particulars |
SLEP1681 |
TDS Meter, Digital, A.T.C. , Waterproof, Pocket Model |
TDS Meter, Digital, Portable
Technical Specifications
- Display: 3½ Digit LCD
- Range: 2 Ranges 0-2000 ppm 0-20 ppt
- Temperature Compensation: NA
- Cell Constraint Adjustment: Pre-adjustable
- Conductivity Cell: Platinum DIP
- Measuring Frequency: 1000 Hz
- Accuracy: ±1% FSI
- Power: 1 x 9V Battery
- Dimensions: 85 x 28 x 165 mm
- Weight: 0.8 kg (approx.)
Accessories
- TDS Cell
- Operation Manual
- Dust Cover
Catalog No. |
Particulars |
SLEP1691 |
TDS Meter, Digital, Portable |
TDS Meter, Digital, Table Model
- Highly Stable and Accurate
- Cell Constant Adjustment Facility
- Temperature Coefficient Correction facility
Technical Specifications
- Display: 3½ Digit LCD
- Range: 5 Ranges
- 0-1000 ppt Mohs/cm
- Temperature Compensation: Manual 0-50°C
- Cell Constraint Adjustment: Adjustable
- Conductivity Cell: Platinum DIP
- Measuring Frequency: 1000 Hz
- Accuracy: ±1% FSI
- Power: 230V+10%
- Dimensions: 76x275x175 mm
- Weight: 2 kg (approx.)
Accessories
- TDS Cell
- Operation Manual
- Dust Cover
Catalog No. |
Particulars |
SLEP1701 |
TDS Meter, Digital, Table Model |