Code | MCC400 | |
---|---|---|
Viewing Head | 97mm | |
Eyepiece | High-point , extra wide field eyepiece EW10×/ 20 | |
Infinite Plan Achromatic Objective | 4×/ 0.1 | |
5×/ 0.12 | optional | |
10×/ 0.25 | ||
20×/ 0.40 | ||
40×/ 0.60 | ||
50×/ 0.75 | optional | |
100×/ 0.80 | optional | |
Nosepiece | Quintuple nosepiece | |
Stage | Plain stage | |
Attachable mechanical stage, X-Y coaxial control, moving range 120×78mm | optional | |
Double layer mechanical stage 226×178mm,Moving range 50×50mm | optional | |
Auxiliary stage | optional | |
Focusing | Coaxial coarse & fine adjustment, Vertical objective movement, Coarse stroke 37.7mm per rotation, Fine stroke 0.2mm per rotation | |
Kohler Illumination | Halogen lamp 6V/ 30W | |
Filter | Blue, Yellow, Green and Ground Glass | |
Polarization Attachment | ||
Photo Attachment | optional | |
Video Adapter | Video adapter with C mount | optional |
Code | MCC410 | MCC413 | MCC416 | MCC419 | |
---|---|---|---|---|---|
Optical System | Infinite optical system | ||||
Eyepiece | Extral wide field eyepiece EW10×/22 | ||||
Infinite plan Achromatic Objective |
5×/ 0.12/ ∞/ - (BF) | ||||
10×/ 0.25/ ∞/ - (BF/DF) | |||||
20×/ 0.4/ ∞/ 0 (BF/DF) | |||||
50×/ 0.75/ ∞/ 0 (BF) | |||||
100×/ 0.8/ ∞/ 0 (BF) | |||||
40×/ 0.65/ ∞/ 0.17 | |||||
100×/ 1.25/ ∞/ 0.17 | |||||
5×/ 0.12/ ∞/ - (BF/DF) | optional | optional | |||
40×/ 0.6/ ∞/ 0 (BF/DF) | optional | optional | optional | optional | |
50×/ 0.75/ ∞/ 0 (BF/DF) | optional | optional | |||
100×/ 0.8/ ∞/ 0 (BF/DF) | optional | optional | |||
DIC | 20×,100× | optional | optional | ||
Maximum Sample Height |
30mm | ||||
50mm | |||||
Viewing Head | Siedentopf trinocular viewing head, inclined at 30°, interpupillarty distance 48mm-75mm | ||||
Incident light | 24V/100W Halogen light, lightness adjustable | ||||
Kohler illumination and aspherical condenser | |||||
Polarizer and analyzer | optional | optional | optional | optional | |
An integrate device foe polarizer and analyzer | optional | optional | optional | optional | |
Blue,Green,Yellow and Ground glass | |||||
Transmitted light |
Swing-out condenser NA0.9/ 0.25 | ||||
24V/ 100W Halogen light and aspherical condenser | |||||
Blue filter | |||||
Filter | ND25, ND6 | optional | optional | optional | optional |
Focusing | Coaxial coarse and fine adjustment, fine division 1μm | ||||
Nosepiece | Backward quintuple nosepiece | ||||
Stage | Non-porous double layer mechanical stage 186X138mm/74mmX50mm | ||||
Double layer mechanical stage 186×138mm/ 74mm×50mm | |||||
Glass specimen preparation plate | optional | optional | optional | optional | |
Specimen preparation plate | |||||
Slide glass | |||||
Specimen Presser | optional | optional | optional | optional | |
Photo Attachment | optional | optional | optional | optional | |
Video Attachment | C Mount 1×,0.5× | optional | optional | optional | optional |